Vibration sensors

Technical characteristics

Name of parameter Values
Outlet of vibration inverter on direct current 4-20mA
Measuring range of virbrospeed from 1 to 32 mm/sec
Conversion ratio, nominal value 0,5 mA ×mm-1×sec
Deviation of conversion ratio from nominal value, %, not more than 10
Frequency range, Hz 10 .. 1000
The limits of irregularity of amplitude-frequency characteristics in the frequency range: 10 .. 1000 Hz, %, not more +10 -20
Decay of amplitude-frequency characteristics beyond the range In accordance with GOST ISO 295497.
Relative ratio of the cross conversion, %not more than 5
Supply voltage, v 20..30
Maximal current consumption, mA 20
Transition time, 4-20mA 60 seconds
line resistance at supply voltage 24V, m 200400
Insulation, V 500
Temperature working range of sensor, Up to+70
Impact,g 300
Structure of body frame (protection degree) I 67
Weight, g 150
Dimensional sizes, mm 2148
Material of body frame 121810
Fixation crew6
Cable length, m 1

 